APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

Review the specifications, then ask our team for current pricing and availability.

NetShelter Rack PDU Advanced, Switched Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

Part APDU10350SM · UPC 731304439745

Catalog availability is a file snapshot. Call to confirm stock and pricing before ordering.

Add to cart Continue browsing
  • Maximum Outlet Density All models include 40, 42, or 48 outlets
  • Space Saving
  • High Power Capacity Models now available to provide up to 34.6kW
  • APC Locking Power Cord Compatible Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet
  • Circuit Breaker Monitoring
  • Alternating Phase
  • 60ºC (140ºF) Operating Temperature
  • Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU
  • Hydraulic Magnetic Circuit Breakers
  • Live Swap Network Management Card
  • Environmental Sensor Support
  • Color LCD Display
  • Dual Network Ports

About this product

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Manufacturer warranty information

3 years repair or replace

Design

PDU types
Metered, Metered-by-outlet, Switched
Type
Three-phase
Rack capacity
0U
Mounting
Vertical
Product colour
Black
Display
LCD
On/off switch
No

Ports & interfaces

AC outlets quantity
48 AC outlet(s)
Power plug
IEC 60309
AC outlet types
C13 coupler, C15 coupler, C19 coupler, C21 coupler

Power

Nominal input voltage
400 V
AC input frequency
50 - 60 Hz
Maximum current
32 A
Nominal output voltage
230 V
Output voltage
230 V
Load capacity
22100 VA

Certificates

Certification
CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1

Operational conditions

Operating temperature (T-T)
-5 - 60 °C
Storage temperature (T-T)
-25 - 65 °C
Operating relative humidity (H-H)
5 - 95%
Storage relative humidity (H-H)
5 - 95%
Operating altitude
0 - 15240 m

Weight & dimensions

Width
56 mm
Depth
75 mm
Height
1780 mm
Weight
9.6 kg

Packaging data

Package weight
12.6 kg
Package width
262 mm
Package depth
132 mm
Package height
1980 mm

Logistics data

Total carbon footprint (kg of CO2e)
16737.93

Specifications and images: Database Right data-sheet 2026 Icecat. All rights reserved. Supplied as is, without warranty. Specs Icecat · Open Content License

Development preview

Review your request.

No message has been sent. This draft stays on this device.