Product specifications

APC Smart-UPS 3000VA RM 2U LCD 208V uninterruptible power supply (UPS) 3 kVA 2700 W 2 AC outlet(s)

Review the specifications, then ask our team for current pricing and availability.

Smart-UPS 3000VA RM 2U LCD 208V

Part SMT3000RMT2U · UPC 731304279556

Catalog availability is a file snapshot. Call to confirm stock and pricing before ordering.

Add to cart Continue browsing

About this product

Intuitive LCD interface

Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.

Predictive replace battery date

Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.

Green mode

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Energy meter

Provides actual kilowatt hours of usage for energy conscious users.

Outlet group control

Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).

Sequenced shutdown and restart

Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).

Pure sine wave output on battery

Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

Single switched outlet group

Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.

Wide input voltage range

Designed for harsh electrical environments to save battery life.

StruxureWare

Central compatible Enables centralized management via StruxureWare Central.

Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

High online efficiency

Reduces utlility costs, generates less heat.

LED Indicators

Provide easy-to-read status of the unit and utility power conditions.

Cold-start capable

Provides temporary battery power when the utility power is out.

Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Disconnected battery notification

Warns when a battery is not available to provide backup power.

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.

Adjustable voltage-transfer points

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Adjustable voltage sensitivity

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible alarms

Provides notification of changing utility power and UPS conditions

User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

USB connectivity

Provides management of the UPS via a USB port (not available on all models).

Serial Connectivity

Provides management of the UPS via a serial port.

Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.

Boost and Trim Automatic

Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Network manageable

Provides remote management of the UPS over the network.

Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Predicitive failure notification

Provides early-warning fault analysis ensuring proactive component replacement.

Boost and Trim

Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.

Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Disconnected battery notification

Warns when a battery is not available to provide backup power.

Network manageable

Provides remote management of the UPS over the network.

Audible alarms

Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

LED status indicators

Quickly understand unit and power status with visual indicators.

Serial Connectivity

Provides management of the UPS via a serial port.

USB connectivity

Provides management of the UPS via a USB port (not available on all models).

Disconnected battery notification

Warns when a battery is not available to provide backup power.

User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair

Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Predictive failure notification

Provides early-warning fault analysis ensuring proactive component replacement.

Resettable circuit breakers

Enables a quick recovery from overload events.

Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Adjustable voltage-transfer points

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Adjustable voltage sensitivity

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Features

Output power capacity
3 kVA
Output power
2700 W
Input operation voltage (min)
141 V
Input operation voltage (max)
255 V
Input frequency
50/60 Hz
Output operation voltage (max)
208 V
Surge energy rating
320 J
Noise level
55 dB

Ports & interfaces

AC outlet types
NEMA L6-20R
AC outlets quantity
2 AC outlet(s)
USB 2.0 ports quantity
1

Battery

Battery recharge time
3 h

Design

Form factor
Rackmount
Rack capacity
2U
Product colour
Black

Operational conditions

Operating temperature (T-T)
0 - 40 °C
Storage temperature (T-T)
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%

Certificates

Certification
FCC Part 15 Class A, UL 1778

Weight & dimensions

Width
480 mm
Depth
690 mm
Height
86 mm
Weight
44.3 kg

Packaging data

Package weight
51.7 kg

Other features

Package dimensions (WxDxH)
600 x 980 x 254 mm